In a hypothetical OTDR test, the event table shows −0.12 dB at a fusion splice. From the other end of the link, the same splice shows +0.32 dB. Those readings appear to disagree, but they can both be consistent with a splice whose estimated loss is 0.10 dB.
The difference comes from what the instrument measures. An optical time-domain reflectometer (OTDR) estimates event loss from the light scattered back toward it along the fiber. If the fibers on either side of a splice return different levels of backscatter, the same splice can look better in one direction and worse in the other. A negative value is an apparent gain in the trace. It does not mean the splice amplifies the signal. EXFO’s application note on OTDR gainers explains why the bias reverses when the test direction is reversed.
What causes an OTDR gainer?
At a transition between dissimilar fiber sections, the backscatter level beyond the joint can step up even though transmitted power falls through the joint. The OTDR may interpret that upward step as negative loss. From the far end, the step can appear as an exaggerated loss. Differences in mode-field diameter can contribute to this effect, including across reels of the same nominal fiber grade.
A joint between G.652.D feeder fiber and G.657.A access fiber is one place where this effect can show up. A trace shape alone does not identify the fiber grade or prove a mismatch. Check the route records and splice map, and use the single-mode fiber grade guide when specifying the materials for a future section.
Find the same splice from the far end
Imagine an 8.0 km link with a closure 3.0 km from end A. Once launch leads are excluded and distances are referenced to the link ends, look for that closure about 5.0 km from end B. Event numbers need not match. If the reverse file shows a splice at 3.0 km from B, check the route map before pairing it with the forward reading. Averaging losses from two different splices can produce a convincing number for a splice nobody actually tested.
Pair the same event before averaging
- Obtain the two directions for the same fiber at the same test wavelength. Keep the original trace files and label each with its start and end points. Use launch and receive leads as required by the project test method.
- Match the event to the same physical splice using the route and closure records. A splice near the start of the A-to-B trace will be near the end of the B-to-A trace. Reversed event numbers and different lead lengths can make a row-by-row comparison misleading.
- Check that the event is resolved on both traces. If a nearby reflection, another event or insufficient trace quality prevents a reliable reading, use the project method to retest before calculating the average.
- Average the signed event losses in dB from the two directions. Keep both raw readings and compare the resulting estimate with the project’s acceptance limit at that wavelength.
| Illustrative reading at the same event and wavelength | Loss |
|---|---|
| A to B | −0.12 dB |
| B to A | +0.32 dB |
| Signed average | 0.10 dB |
Signed average (−0.12 + 0.32) ÷ 2 = 0.10 dB. These numbers are a worked example. The project specification supplies the actual pass/fail limit. Averaging absolute values would give the wrong answer because it would discard the sign of the apparent gain.
When should you retest or reopen a splice?
Do not order rework from the higher direction alone. First check the fiber identity, wavelength, event correspondence and trace quality. A cleanly resolved event with a bidirectional average within the applicable limit may be accepted under the project test method. If the matched average exceeds the limit, or the event cannot be reliably isolated in either trace, follow the project’s retest and escalation criteria. A reverse trace from a different fiber or wavelength cannot resolve the original event.
If you can access only one end, retain that trace and state that the event has a one-direction reading. If the contract calls for bidirectional acceptance, arrange the second measurement or document the approved exception before closing the item. For end-to-end insertion loss, use the specified optical loss test method and reference setup. An OTDR event average does not replace that link measurement. See OTDR vs OLTS for how the two reports fit together.
What to put in the acceptance record
For each disputed event, retain the route and fiber ID, closure or splice ID, test wavelength, both signed readings, the calculated average, the applicable limit, and references to the raw trace files. Record any unresolved or retested events separately so a reviewer can reproduce the decision.
For the test plan, specify the deliverable in one sentence. “Record the A-to-B and B-to-A OTDR traces at the required wavelength for each specified fiber. Report the signed average for the same physical splice, and retain both raw traces.” Pair that with the project’s event limits and its separate end-to-end loss requirements.