Home/News

Nov 19, 2026

Fiber Optic Cable Color Code for 48-Fiber Cables

Blue and white equipment along an aisle in Ebocom’s fibre colouring workshop
Blue and white equipment along an aisle in Ebocom’s fibre colouring workshop
The fibre colouring line in Ebocom’s workshop.

Which fiber is number 13 in a 48-count loose-tube cable? It could be the blue fiber in the orange tube. It could also be the blue fiber in the green tube. Both answers fit a common fiber optic cable color code. What changes the answer is the number of fibers inside each tube.

How to read the 12-position fiber optic cable color code

Start at the outside of the group and work inward. Identify the buffer tube, then the individual fiber inside it. Under the common TIA-598 sequence, blue means position 1 at either level. That makes “blue” alone an incomplete entry on a splice sheet. The Fiber Optic Association publishes the following sequence and notes that operator or national conventions can differ. FOA color code reference.

Positions within one group of twelve
Position Color Position Color
1 Blue 7 Red
2 Orange 8 Black
3 Green 9 Yellow
4 Brown 10 Violet
5 Slate (gray) 11 Rose
6 White 12 Aqua

Find fibers 13 and 24 on two different 48-count drawings

Take two example drawings. Both use consecutive numbering, fully populated tubes, and the sequence above for both tubes and fibers. Drawing A has four tubes of twelve. Drawing B has eight tubes of six. These are illustrative constructions. The drawing supplied with your cable determines which map to use.

Fiber ID A · Four tubes of twelve B · Eight tubes of six
13 Tube 2, fiber 1 · orange / blue Tube 3, fiber 1 · green / blue
24 Tube 2, fiber 12 · orange / aqua Tube 4, fiber 6 · brown / white

On drawing B, write the ranges on paper: blue tube 1–6, orange 7–12, green 13–18, brown 19–24. You can now locate fiber 24 without opening the cable. A useful cross-check is to run the calculation backwards. Brown is the fourth tube. Three complete six-fiber tubes precede it, so the white fiber in that tube is 18 + 6 = 24.

What changes at a splice between the two designs?

Suppose the splice plan calls for fiber 24 on cable A to continue as fiber 24 on cable B. The tray record should read “A · orange tube · aqua fiber → B · brown tube · white fiber.” A shorthand instruction to join matching colors would point the crew to the wrong place. Keep the cable identifier on each side of the arrow, especially when more than two cables enter the closure.

A spare fiber also needs an address. If the plan assigns 24 to a future branch, enter the tube and fiber on the reserve list now. A technician returning later can find the reserved strand even if the original crew is unavailable. After splicing, associate each test record with that same fiber ID and its two endpoints. Ebocom’s guide to OTDR and OLTS records.

What to put on the cable order

For a retrofit, send Ebocom the existing cable’s tube chart and one representative splice entry. For a new build, specify the fiber count, fibers per tube and required identification convention. Ask for the proposed cross-section with every populated tube identified. If the drawing shows filler elements or repeated colors, ask the supplier to label the fillers and show the stripe or other group marker on the legend.

One concise order note for drawing A would be: “48 fibers, 4 populated tubes × 12. Please return the tube and fiber sequence with the drawing revision. Our splice schedule numbers fibers consecutively from 1 to 48.” Attach that schedule when you request a cable quotation. It gives the buyer and the splice crew the same reference before the first drum arrives.